1000W
RATED OUPUT POWER | 1000W |
Max. PV Power | 1000W |
Max. PV Array Open Circuit Voltage | 145 VDC |
MPPT Range @ Operating Voltage | 15 VDC~115 VDC |
Number of MPP Tracker | 1 |
Nominal Output Voltage | 220/230/240 VAC |
Output Voltage Range | 184 - 265 VAC |
Nominal Output Current | 4.3A |
Power Factor Range | >0.99 |
Maximum Conversion Efficiency (DC/AC) | 90% |
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
Rating of AC Transfer Relay | 30A |
Nominal Output Voltage | 220/230/240 VAC |
Output Waveform | Pure Sine Wave |
Efficiency (DC to AC) | 93% |
Nominal DC Voltage | 12 VDC |
Maximum Charging Current (from Grid) | 60A |
Maximum Charging Current (from PV) | 80A |
Maximum Charging Current | 140A |
Dimension D X W X H (mm) | 440 x 300 x 100 |
Net Weight (kgs) | 8 |
Parallel-able | N/A |
External Safety Box (Optional) | Yes |
Communication | USB or RS232/Dry-Contact |
Humidity | 0 ~ 90% RH (No condensing) |
Operating Temperature | 0 to 50°C |
Introduction:
This hybrid PV inverter can provide power to connected loads by utilizing PV power, utility power and battery power.
Depending on different power situations, this hybrid inverter is designed to generate continuous power from PV solar modules (solar panels), battery, and the utility. When MPP input voltage of PV modules is within acceptable range (see specification for the details), this inverter is able to generate power to feed the grid (utility) and charge battery. Galvanic isolation designed between PV/DC and AC output, so that user could connect any type of PV array to this Hybrid inverter. See Figure 1 for a simple diagram of a typical solar system with this hybrid inverter.
Product Overview:
NOTE: For parallel model installation and operation, please check separate parallel installation guide for the details.
1. LCD display
2. Status indicator
3. Charging indicator
4. Fault indicator
5. Function buttons
6. Power on/off switch
7. Grid connectors
8. AC output connectors (Load connection)
9. PV connectors
10. Battery connectors
11. Circuit breaker
12. Parallel communication cable
13. Current sharing cable
14. Dry contact
15. RS-232 communication port
16. USB communication port
This hybrid PV inverter can provide power to connected loads by utilizing PV power, utility power and battery power.
Depending on different power situations, this hybrid inverter is designed to generate continuous power from PV solar modules (solar panels), battery, and the utility. When MPP input voltage of PV modules is within acceptable range (see specification for the details), this inverter is able to generate power to feed the grid (utility) and charge battery. Galvanic isolation designed between PV/DC and AC output, so that user could connect any type of PV array to this Hybrid inverter. See Figure 1 for a simple diagram of a typical solar system with this hybrid inverter.
Product Overview:
NOTE: For parallel model installation and operation, please check separate parallel installation guide for the details.
1. LCD display
2. Status indicator
3. Charging indicator
4. Fault indicator
5. Function buttons
6. Power on/off switch
7. Grid connectors
8. AC output connectors (Load connection)
9. PV connectors
10. Battery connectors
11. Circuit breaker
12. Parallel communication cable
13. Current sharing cable
14. Dry contact
15. RS-232 communication port
16. USB communication port